Click to enlarge image
|
Model Number |
SLM 300C/800C/990C |
The SONDAR SLM300C, 800C and 990C are a highly developed ultrasonic level measurement system, which provides in non contacting level measurement for a wide variety of applications in liquid and solid. This unit is designed for mounting above material level being measured. If offers the integral nose thread allowing a screw-fit of flange-fit to tanks or mounting-brackets.
Features
- High accuracy and resolution
- Aluminum die-casting body
- Explosion-proof structure
- Various extension pipe 30cm to 100cm
- Two wire loop-powered
- Display in distance, level, or space is selectable at user's need
Technical Specification
| Physical |
|
Dimension
|
Overall 120(D)x260(H)mm Sensor 67(D)x136(H)mm
|
|
Mounting
|
2 1/2" NPT
|
|
Weight
|
Nominal 2.8Kg
|
|
Sensor Material
|
Polypropylene
|
|
Case Material
|
Aluminum
|
| Performance |
|
Accuracy
|
0.2% of measured range
|
|
Resolution
|
1mm
|
|
Measuring range
|
0.3m~ 3m/ 8m/10m
|
|
Beam Angle
|
4° at -3dB
|
|
Damping Rate
|
Adjustable 0.1m/min to 100m/min
|
|
Temperature Compensation
|
Fully compensated
|
| Environmental |
|
IR Rrating
|
IP65
|
|
Temperature
|
-20°C~85°C
|
|
Pressure
|
Up to 2Bar
|
| Outputs & Power Supply |
|
Analog Output
|
4~20mA into max 750Ω
|
|
Display
|
4 Digit Numeric LCD
|
|
Power Supply
|
DC20~30V
|
|
Supply Current
|
Less than 0.021A
|
|
Type
|
SLM-300C - 3 meter SLM-800C - 8 meter SLM-990C - 10 meter
|
Dimension

Terminal Connection

|
|
|
|
| |
|
|
|